NEU GRAND LIBRARY
Opening Hours: Monday-Saturday, 08:00-20:00 | E-mail: library@neu.edu.tr
 

You are not logged in Show Basket
  Home     Advanced Search     Back  
  Brief display     MARC Display     Reserve  
Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant Placement. (Ozan, Oğuz,)
Bibliographical information (record 266613)
Help
Clinical Accuracy of 3 Different Types of Computed Tomography-Derived Stereolithographic Surgical Guides in Implant Placement.
Author:
Ozan, Oğuz, Search Author in Amazon Books

Publisher:
W. B. Saunders Co-Elsevier Inc.,
Edition:
2009.
Classification:
WU 29
URL:

http://library.neu.edu.tr:2048/login?url=http://dx.doi.org/10.1016/j.joms.2008.09.033
Detailed notes
    - Purpose: Presurgical planning is essential to achieve esthetic and functional implants. The goal of this clinical study was to determine the angular and Linear deviations at the implant neck and apex between planned and placed implants using stereolithographic (SIA) surgical guides. Patients and Methods: A total of 110 implants were placed using SLA surgical guides generated from computed tomography (CT). All patients used the radiographic templates during CT scanning. After obtaining 3-dimensional CT scans, each implant insertion was simulated on the CT images. SIA surgical guides using a rapid prototyping method including a laser beam were used during implant insertion. A new CT scan was made for each patient after implant insertion. Special software was used to match images of the planned and placed implants, and their positions and axes were compared. Results: The mean angular deviation of all placed implants was 4.1 degrees +/- 2.3 degrees, whereas mean linear deviation was 1.11 +/- 0.7 mm at the implant neck and 1.41 +/- 0.9 mm at the implant apex compared with the planned implants. The angular deviations of the placed implants compared with the planned implants were 2.91 degrees +/- 1.3 degrees, 4.63 degrees +/- 2.6 degrees, and 4.51 degrees +/- 2.1 degrees for the tooth-supported, bone-supported, and mucosa-supported SLA surgical guides, respectively. Conclusion: The results of this study suggested that stereolithographic surgical guides using CT data may be reliable in implant placement, and tooth-supported SLA surgical guides were more accurate than bone- or mucosa-supported SLA surgical guides. (C) 2009 American Association of Oral and Maxillofacial Surgeons
Related links
Items (1)
Barcode
Status
Library
Section
EOL-1397
Item available
NEU Grand LibraryOnline (WU 29 .C55 2009)
Online electronic

NEAR EAST UNIVERSITY GRAND LIBRARY +90 (392) 223 64 64 Ext:5536. Near East Boulevard, Nicosia, TRNC
This software is developed by NEU Library and it is based on Koha OSS
conforms to MARC21 library data transfer rules.