NEU GRAND LIBRARY
Opening Hours: Monday-Saturday, 08:00-20:00 | E-mail: library@neu.edu.tr
 

You are not logged in Show Basket
  Home     Advanced Search     Back  
  Brief display     MARC Display     Reserve  
Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures (Meriç, Gökçe,)
Bibliographical information (record 264997)
Help
Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures
Author:
Meriç, Gökçe, Search Author in Amazon Books

Publisher:
Informa Healthcare,
Edition:
2011.
Classification:
WU 29
URL:

http://library.neu.edu.tr:2048/login?url=http://dx.doi.org/10.3109/00016357.2011.572287
Detailed notes
    - Objective. The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures. Materials and methods. The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated. Results. In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models. Conclusion. It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.
Related links
Items (1)
Barcode
Status
Library
Section
EOL-262
Item available
NEU Grand LibraryOnline (WU 29 .B56 2011)
Online electronic

NEAR EAST UNIVERSITY GRAND LIBRARY +90 (392) 223 64 64 Ext:5536. Near East Boulevard, Nicosia, TRNC
This software is developed by NEU Library and it is based on Koha OSS
conforms to MARC21 library data transfer rules.